Ariston Boiler Error Codes: Causes & How To Fix

Ariston Boiler Error Codes: Causes & How To Fix

If you’re seeing, your boiler is highlighting a specific fault that needs attention. The most common Ariston boiler error codes are low water pressure, ignition failures, circulation problems, and airflow or flue-related faults. 

These are often early warning signs that something inside the system is not working as it should. Some can be resolved quickly at home, while others require a qualified engineer to step in before the problem gets worse.

Ariston Boiler Error Codes: At A Glance

Below is a quick overview of the most common Ariston fault codes so you can identify the issue before diving into the detailed fixes below.

Error Code Meaning
101 Overheating fault
102 Pressure sensor fault
103 Poor water circulation
104 Circulation issue detected
105 Blockage or restricted flow
108 Low system pressure
110 Flow temperature sensor fault
111 Return temperature sensor fault
501 Ignition failure
502 Flame detection fault
601 Fan fault
607 Air pressure switch fault

If you’re based in Glasgow, Ayrshire, Renfrewshire, Lanarkshire or Dumbarton and your Ariston boiler is showing these codes repeatedly, it’s often a sign your system is overdue a service. SwitchHeat engineers regularly fix these exact faults and can usually get your heating back up and running the same day.

Book your boiler service today. 

Excellent ★★★★★Trustpilot
9.9/10 from 40 reviews on Checkatrade
4.9★★★★★ 44 reviews on Google
  • Available Finance Options
  • Quality Workmanship
  • Transparent Pricing
  • Fast Response When You Need Us Most
  • Accredited & Qualified Engineers

Get An Online Boiler Quote

What Causes Ariston Boiler Error Codes?

The causes of Ariston boiler error codes usually relate to pressure issues, restricted water flow, ignition problems, or faulty internal components. Understanding the root cause is key to fixing the issue properly rather than just resetting the boiler.

101 Overheating Fault

The 101 overheating fault code means the boiler has detected that internal temperatures have exceeded safe levels.

This typically happens when heat is not being distributed around your heating system effectively. Instead of circulating through your radiators, the heat builds up inside the boiler. In many UK homes, this is caused by sludge and debris inside the system, especially in older radiators. 

Air trapped in the system or a failing pump can also prevent proper circulation, leading to overheating.

How to fix:

  1. Turn off your boiler and allow it to cool completely
  2. Bleed all radiators in your home to release trapped air
  3. Check that all radiator valves are fully open
  4. Turn the heating back on and reset the boiler
  5. Monitor whether all radiators heat evenly
  6. If some radiators remain cold or the error returns, a power flush or pump repair may be required

102 Pressure Sensor Fault

The 102 error code means the boiler is struggling to read system pressure accurately.

Even if the pressure level is correct, the boiler may behave as if it is too high or too low because the sensor is faulty. Over time, sensors can degrade due to constant exposure to heat and pressure changes, leading to incorrect readings.

How to fix:

  1. Check the pressure gauge on the boiler
  2. Confirm the pressure sits between 1 and 1.5 bar
  3. Reset the boiler
  4. If the error continues despite normal pressure, the sensor will need replacing
  5. Contact a qualified engineer to carry out the repair

103 Circulation Fault

The 103 circulation fault indicates that water is not moving through the system as it should.

This is usually due to blockages, sludge build-up, or restricted pipework. Over time, central heating systems naturally collect rust and debris, which reduces water flow. When circulation slows down, the boiler struggles to distribute heat, triggering a fault.

How to fix:

  1. Turn on your heating and check each radiator
  2. Look for cold spots or radiators that are not heating properly
  3. Bleed radiators to remove trapped air
  4. Reset the boiler
  5. If circulation issues persist, a system clean or power flush may be required
  6. Have an engineer inspect the pump and pipework

104 Circulation Issue Detected

The 104 circulation issue detected is closely related to the 103 fault but often points to a more persistent restriction in water flow.

This can be caused by partially closed valves, internal blockages, or a weakening pump that can no longer move water effectively around the system.

How to fix:

  1. Check that all radiator and isolation valves are fully open
  2. Bleed radiators throughout the property
  3. Reset the boiler
  4. Monitor system performance over the next few hours
  5. If the fault returns, the pump or internal components may need replacing

105 Blockage Or Restricted Flow

The 105 error code means the boiler has detected a significant obstruction in the system.

This is often caused by heavy sludge accumulation, limescale, or debris inside the heat exchanger or pipework. Over time, this restricts water movement and reduces efficiency, eventually triggering a shutdown.

How to fix:

  1. Turn off the boiler
  2. Bleed radiators and check for uneven heating
  3. Reset the boiler
  4. If the issue persists, a professional system clean or power flush is required
  5. In severe cases, components like the heat exchanger may need replacing

Excellent ★★★★★Trustpilot
9.9/10 from 40 reviews on Checkatrade
4.9★★★★★ 44 reviews on Google
  • Available Finance Options
  • Quality Workmanship
  • Transparent Pricing
  • Fast Response When You Need Us Most
  • Accredited & Qualified Engineers

Get An Online Boiler Quote

108 Low Pressure Fault

The 108 low pressure fault is one of the most common Ariston boiler issues and means the system pressure is too low. If you own a Baxi, the same low pressure problem is displayed as the Baxi boiler H0207 error code.

Pressure can drop naturally over time, especially after bleeding radiators or due to small leaks. Without enough pressure, the boiler cannot circulate water effectively.

How to fix:

  1. Locate the pressure gauge on your boiler
  2. Check if it is below 1 bar
  3. Find the filling loop underneath the boiler
  4. Slowly open the valves to allow water into the system
  5. Watch the gauge rise to between 1 and 1.5 bar
  6. Close the valves securely
  7. Reset the boiler
  8. If pressure drops again, there may be a leak or faulty component

110 Flow Temperature Sensor Fault

The 110 flow temperature sensor fault means the boiler cannot accurately measure the temperature of water leaving the unit. Vokera boilers use a different set of codes for similar faults, from A01 ignition failure to A40 low pressure, all listed in our Vokera boiler error codes guide.

This leads to poor temperature control and can cause the boiler to shut down to prevent damage. The issue is usually caused by a faulty sensor or loose wiring.

How to fix:

  1. Reset the boiler
  2. Run your heating and monitor performance
  3. If temperatures are inconsistent or the fault returns, switch off the boiler
  4. Arrange for a sensor replacement by a qualified engineer

111 Return Temperature Sensor Fault

The 111 return temperature sensor fault relates to incorrect readings from water returning to the boiler.

When this sensor fails, the boiler cannot balance heat properly, which affects efficiency and performance.

How to fix:

  1. Reset the boiler
  2. Monitor heating performance
  3. If the issue continues, the sensor will need replacing
  4. Book a professional repair

501 Ignition Failure

The 501 error code means the boiler cannot ignite the gas to produce heat.

This can happen due to interrupted gas supply, worn ignition components, or a faulty gas valve. Over time, ignition parts wear out due to constant use and heat exposure.

How to fix:

  1. Check your gas supply is active
  2. Test another gas appliance such as your hob
  3. Press the boiler reset button
  4. Wait to see if the boiler attempts to ignite
  5. If the fault persists, contact a Gas Safe engineer to inspect internal components

502 Flame Detection Fault

The 502 flame detection fault means the boiler is detecting a flame signal when there is none.

This is typically caused by a faulty flame sensor or electrical issue. The boiler shuts down as a safety precaution.

How to fix:

  1. Turn the boiler off completely
  2. Wait 30 seconds and turn it back on
  3. Reset the system
  4. If the fault returns, the flame sensor or control board will need inspection

601 Fan Fault

The 601 fan fault means the boiler fan is not operating correctly.

The fan is responsible for removing harmful gases from the boiler. If it fails, the boiler will shut down immediately for safety.

How to fix:

  1. Reset the boiler
  2. Listen for the fan when the boiler starts
  3. If no sound is heard or the fault returns, the fan will need replacing
  4. Contact a qualified engineer

607 Air Pressure Switch Fault

The 607 air pressure switch fault indicates a problem detecting airflow through the flue system.

This is often caused by blockages in the flue or a faulty pressure switch. External debris or poor ventilation are common causes in UK homes.

How to fix:

  1. Inspect the external flue for blockages such as leaves or debris
  2. Ensure vents around the boiler are clear
  3. Reset the boiler
  4. If the fault persists, a professional inspection of the flue and pressure switch is required

Book Your Boiler Service With SwitchHeat Today

If your boiler keeps showing Ariston boiler error codes, it’s time to take action before a small issue turns into a full breakdown.

SwitchHeat offers expert boiler servicing and maintenance across Central Scotland, including Glasgow, Ayrshire, Renfrewshire, Lanarkshire and Dumbarton. Whether it’s low pressure, ignition faults, or circulation issues, our engineers will get your system running properly again.

Book your boiler service with SwitchHeat today and keep your heating reliable all year round.

Frequently Asked Questions

Can Power Cuts Cause Boiler Error Codes?

Yes, power cuts can trigger Ariston boiler error codes because the boiler loses its normal operating sequence. When power is restored, the system may restart incorrectly or fail to initialise key components like the fan or sensors. This can lead to temporary fault codes appearing. In most cases, a simple reset will clear the error, but if the code remains, it usually points to an underlying issue that needs attention.

Do Ariston Boilers Lock Out After Multiple Faults?

Yes, Ariston boilers are designed to lock out after repeated faults as a safety measure. Lockout prevents the boiler from continuing to run when there is a risk of damage or unsafe operation, such as failed ignition or overheating. You will usually need to reset the boiler manually, but if the lockout happens more than once, the fault should be properly diagnosed rather than repeatedly reset.

Can Limescale Cause Error Codes In Hard Water Areas?

Yes, limescale is a common cause of Ariston boiler error codes in hard water areas. Over time, limescale builds up inside the heat exchanger and pipework, restricting water flow and reducing heat transfer. This can trigger faults related to overheating, poor circulation, or temperature sensors. Regular servicing and system cleaning help prevent limescale from reaching this stage.

Are Error Codes Different On Newer Ariston Models?

Yes, newer Ariston models often display more detailed or slightly different error codes compared to older boilers. However, the underlying faults remain similar, such as pressure issues, ignition problems, or sensor failures. Always refer to the model-specific manual, as the code format and meanings can vary slightly between ranges.

Should I Reset My Boiler Frequently If Errors Keep Appearing?

No, you should not reset your boiler repeatedly if error codes keep appearing. While a reset can clear a temporary fault, frequent resets can hide the real problem and allow it to worsen over time. If the same error returns after one or two resets, it is best to arrange a proper inspection to prevent further damage or a full breakdown.

Excellent ★★★★★Trustpilot
9.9/10 from 40 reviews on Checkatrade
4.9★★★★★ 44 reviews on Google
  • Available Finance Options
  • Quality Workmanship
  • Transparent Pricing
  • Fast Response When You Need Us Most
  • Accredited & Qualified Engineers

Get An Online Boiler Quote

Good news, we install Boilers in your area!

Instant online quotes, finance available & next day installation.

Get a quote