Vaillant boiler fault codes are short “F” codes that appear on your boiler’s display to tell you exactly why it has stopped working. The most common ones are F22 (low water pressure), F28 (the boiler failed to light), F29 (the flame went out during use), F75 (the pump and pressure sensor aren’t working together properly) and F32 (a fan problem, often caused by a frozen condensate pipe in winter). Other codes cover temperature sensors, the gas valve, overheating and the flue. If your display is showing an hourglass rather than an F code, that isn’t a fault at all, so read what the egg timer symbol on a Vaillant boiler means before you start troubleshooting.
Most Vaillant fault codes are your boiler’s way of protecting itself, and many of them can be cleared with a simple check such as topping up the pressure or thawing a pipe. Others need a Gas Safe engineer.
Below, you’ll find every Vaillant fault code explained in plain English, along with what causes it and how to fix it, so homeowners and landlords across Glasgow, Dumbarton, Renfrewshire, Ayrshire, Lanarkshire and the rest of Central Scotland know exactly what to do next.
Vaillant Boiler Fault Codes: A Quick Overview
The table below gives you a quick summary of all the common Vaillant boiler error codes.
| Fault Code | What It Means |
| F0 | Flow temperature sensor open circuit (no signal) |
| F1 | Return temperature sensor open circuit (no signal) |
| F2 | Hot water outlet sensor open circuit |
| F3 | Hot water cylinder sensor open circuit |
| F4 | Temperature sensor fault on some older models |
| F5 | Flue gas or external air sensor open circuit |
| F10 | Flow temperature sensor short circuit |
| F11 | Return temperature sensor short circuit |
| F12 | Hot water outlet sensor short circuit |
| F13 | Hot water cylinder sensor short circuit |
| F20 | Overheat safety thermostat (safety temperature limiter) has tripped |
| F22 | Low water pressure or dry fire |
| F23 | Temperature gap between flow and return is too large |
| F24 | Water temperature rising too quickly |
| F25 | Flue gas temperature too high |
| F26 | Gas valve not receiving power or not responding |
| F27 | Flame detected when the gas valve is closed (flame simulation) |
| F28 | Boiler failed to light on start up |
| F29 | Flame lost during operation |
| F32 | Fan speed fault, often linked to frost or a frozen condensate pipe |
| F33 | Air pressure switch fault (older models) |
| F49 | Low voltage on the eBUS control connection |
| F54 | Gas supply problem stopping the burner lighting |
| F61 | Gas valve control fault |
| F62 | Gas valve slow to shut off |
| F63 | Memory (EEPROM) fault on the circuit board |
| F64 | Electronics or sensor fault |
| F65 | Circuit board temperature too high |
| F67 | Flame signal doesn’t make sense to the boiler |
| F70 | Invalid device ID after a part replacement |
| F71 | Flow sensor reading stuck at the same value |
| F72 | Flow and return sensors giving mismatched readings |
| F73 | Water pressure sensor signal too low |
| F74 | Water pressure sensor signal too high |
| F75 | No pressure rise detected when the pump starts |
| F76 | Heat exchanger overheat protection has tripped |
| F77 | Condensate pump or flue gas damper fault |
| F78 | Hot water outlet sensor problem with an external controller |
| F83 | Little or no temperature change when the burner lights |
| F84 | Flow and return temperature difference doesn’t make sense |
| F85 | Flow and return sensors fitted to the same or wrong pipe |
| F86 | Underfloor heating safety contact open |
| F87 | Ignition electrode not connected |
| F88 | Gas valve not connected |
| F89 | Pump not connected or the wrong pump fitted |
Not every code appears on every Vaillant model, and older boilers can use slightly different meanings. If you’re unsure, check the user manual for your exact boiler, which you’ll find listed on the model plate behind the front panel.
If your Vaillant is showing faults more and more often, it might be time to think about the bigger picture. SwitchHeat installs new, A rated boilers for homeowners and landlords across Glasgow, Dumbarton, Renfrewshire, Ayrshire, Lanarkshire and throughout Central Scotland. Request a free new boiler quote today and find out how affordable a reliable, efficient replacement can be.
-
Available Finance Options
-
Quality Workmanship
-
Transparent Pricing
-
Fast Response When You Need Us Most
-
Accredited & Qualified Engineers
Vaillant Boiler Fault Codes: Causes & How To Fix
Vaillant boiler fault codes each have their own causes and fixes, so we’ve broken them down one by one below, with simple steps you can follow and clear guidance on when to call a Gas Safe engineer.
F0 Flow Temperature Sensor Open Circuit
The F0 code means the boiler has lost the signal from its flow temperature sensor, the small sensor that measures the water leaving the boiler. Without that reading, the boiler can’t control the burner safely, so it stops. The usual causes are a failed sensor, a loose plug or broken wire, or damp affecting the connection.
- Switch the boiler off at the mains for 30 seconds, then turn it back on.
- Check for any signs of water dripping inside or around the boiler.
- If F0 returns, book a Gas Safe engineer to test the sensor and its wiring.
- Have the sensor or wiring replaced if it’s found to be faulty.
F1 Return Temperature Sensor Open Circuit
The F1 code means the boiler can’t get a reading from its return temperature sensor, which measures water coming back from the radiators. It’s normally caused by a failed sensor, a loose plug or damaged wiring.
- Reset the boiler once and see if the code clears.
- Look for leaks around the boiler that could affect the wiring.
- Book a Gas Safe engineer to test the return sensor and its connections.
- Replace the sensor or wiring if it’s faulty.
F2 Hot Water Outlet Sensor Open Circuit
The F2 code means the hot water sensor on a combi boiler has stopped sending a signal. The boiler may still provide heating, but hot water can be affected. A failed sensor or a loose connection is the most likely cause.
- Check whether your heating still works while the hot water doesn’t.
- Reset the boiler and run a hot tap to test.
- Book a Gas Safe engineer to test the hot water sensor.
- Have the sensor or connector replaced if needed.
F3 Hot Water Cylinder Sensor Open Circuit
The F3 code appears on system and regular boilers with a hot water cylinder, and it means the cylinder sensor has lost its signal. The cause is usually a faulty sensor, a disconnected cable or a wiring fault between the cylinder and the boiler.
- Check that the cylinder sensor cable hasn’t been knocked or unplugged in the airing cupboard.
- Reset the boiler and see if the fault clears.
- Book a Gas Safe engineer or heating engineer to test the sensor and wiring.
- Replace the sensor if it’s faulty.
F4 Temperature Sensor Fault
The F4 code appears mainly on older Vaillant models and points to a temperature sensor that the boiler can no longer read. It’s usually caused by a worn sensor, loose or corroded wiring, moisture in the electrics or occasionally a circuit board fault. You can read our full guide to the F4 error code for more detail.
- Switch the boiler off at the mains for 30 seconds, then back on.
- Check for drips or damp around the boiler casing.
- Book a Gas Safe engineer to test the sensors and wiring.
- Have any faulty sensor or connector replaced.
F5 Flue Gas Or External Air Sensor Open Circuit
The F5 code means a sensor linked to the flue or air intake has lost its signal on models that use one. A damaged sensor, a broken wire or a loose plug are the usual causes.
- Reset the boiler once.
- Check outside that the flue terminal hasn’t been damaged.
- Book a Gas Safe engineer to test the sensor and its wiring.
- Have the faulty part repaired or replaced.
F10 Flow Temperature Sensor Short Circuit
The F10 code means the flow sensor is giving a reading that’s impossibly high, usually because of a short circuit. Water getting into the sensor plug, a damaged cable or a failed sensor are common causes.
- Look for leaks dripping onto pipework inside the boiler casing.
- Switch the boiler off at the mains if you can see water near the electrics.
- Book a Gas Safe engineer to test the flow sensor and wiring.
- Replace the sensor and fix any leak before restarting.
F11 Return Temperature Sensor Short Circuit
The F11 code means the return sensor has shorted out, so the boiler sees a reading it can’t trust. Damp, damaged wiring or a failed sensor are the usual reasons.
- Check for water leaks around the boiler.
- Reset the boiler once to see if it clears.
- Book a Gas Safe engineer to test the return sensor.
- Have the sensor or wiring replaced if faulty.
F12 Hot Water Outlet Sensor Short Circuit
The F12 code means the hot water outlet sensor on a combi has shorted. It usually comes down to a failed sensor or moisture on its connection, and it can affect your hot water.
- Reset the boiler and test a hot tap.
- Check for leaks under the boiler.
- Book a Gas Safe engineer to test the hot water sensor.
- Replace the sensor if needed.
F13 Hot Water Cylinder Sensor Short Circuit
The F13 code means the cylinder sensor on a system or regular boiler has shorted. A damaged cable, a pinched wire or a faulty sensor are the common causes.
- Check the cylinder sensor cable in the airing cupboard for any obvious damage.
- Reset the boiler.
- Book an engineer to test the sensor and wiring.
- Have the sensor or cable replaced.
F20 Safety Temperature Limiter Tripped
The F20 code means the boiler’s overheat safety device has tripped because the water got too hot. Poor circulation is the most common cause, often from a stuck pump, low pressure, trapped air, sludge or closed valves. Our full F20 fault code guide explains each cause in detail.
- Switch the boiler off and let it cool for at least 30 minutes.
- Check the pressure is between 1 and 1.5 bar and top up if needed.
- Bleed your radiators to release trapped air.
- Reset the boiler and listen for the pump running.
- If F20 returns, book a Gas Safe engineer to check the pump and system.
F22 Low Water Pressure
The F22 code means the water pressure in your heating system is too low for the boiler to run safely, which Vaillant calls dry fire protection. It’s usually caused by a leak, a faulty pressure relief valve, bleeding radiators without topping up, or a faulty pressure sensor. Read our guide to the F22 fault code for a full walkthrough.
- Check the pressure gauge on the boiler.
- If it’s below 1 bar, find the filling loop under the boiler.
- Open the valves slowly until the pressure reaches around 1.2 bar, then close them.
- Reset the boiler.
- If the pressure keeps dropping, book an engineer to find the leak.
F23 Temperature Gap Between Flow And Return Too Large
The F23 code means the water leaving the boiler is much hotter than the water coming back, which usually points to water moving too slowly. A weak pump, low pressure, air, sludge or a faulty sensor are the main causes. See our F23 fault code article for more.
- Check and top up the pressure if it’s low.
- Bleed your radiators.
- Listen for the pump running when the heating comes on.
- Reset the boiler.
- Book a Gas Safe engineer if the fault returns.
F24 Water Temperature Rising Too Quickly
The F24 code means the water heated up too fast, which happens when there isn’t enough water moving through the boiler. Common causes include a sticking pump, low pressure, air in the system, sludge or closed valves. Our F24 fault code guide covers each one.
- Check the pressure and top up to around 1.2 bar if needed.
- Make sure the valves under the boiler are fully open.
- Bleed your radiators.
- Reset the boiler and check the pump is running.
- Book an engineer if F24 keeps coming back.
F25 Flue Gas Temperature Too High
The F25 code means the gases leaving through the flue are too hot, or the flue safety device has tripped. A blocked flue, a frozen condensate pipe, poor water flow or a faulty sensor can all be to blame. Read our full F25 fault code guide for more.
- Check the flue terminal outside for blockages like leaves or snow.
- Thaw a frozen condensate pipe with warm, not boiling, water.
- Check the boiler pressure and bleed radiators if needed.
- Reset the boiler.
- Book a Gas Safe engineer if the fault returns.
F26 Gas Valve Not Responding
The F26 code means the gas valve isn’t getting power or its small internal motor isn’t moving properly. A worn gas valve, loose wiring, a circuit board fault or a weak gas supply can cause it. Our F26 fault code guide has the full details.
- Check other gas appliances are working and any prepayment meter has credit.
- Reset the boiler once.
- If F26 returns, don’t keep resetting it.
- Book a Gas Safe engineer to test the gas valve and wiring.
F27 Flame Simulation
The F27 code means the boiler sensed a flame when the gas valve should have been closed. Damp around the electrode or circuit board, a gas valve that isn’t sealing fully, a faulty electrode or a board fault are the usual causes. Read more in our F27 fault code guide.
- Check for leaks or damp around the boiler.
- Make sure the condensate pipe isn’t frozen or blocked.
- Don’t keep resetting the boiler if F27 returns.
- Book a Gas Safe engineer to check the gas valve and electrode.
F28 Ignition Failure On Start Up
The F28 code means the boiler tried to light but couldn’t detect a flame after several attempts. Common causes include a gas supply problem, an empty prepayment meter, a frozen condensate pipe, a faulty ignition electrode or a failing gas valve. Our F28 fault code article walks through each cause.
- Check your gas hob works and your meter has credit.
- Make sure the gas isolation valve under the boiler is open.
- Check the condensate pipe isn’t frozen.
- Reset the boiler once.
- Book a Gas Safe engineer if it still won’t light.
-
Available Finance Options
-
Quality Workmanship
-
Transparent Pricing
-
Fast Response When You Need Us Most
-
Accredited & Qualified Engineers
F29 Flame Loss During Operation
The F29 code means the boiler lit successfully but then lost its flame while running. This is often caused by an interrupted gas supply, a frozen or blocked condensate pipe, a faulty flame sensor or a flue problem. See our full guide to the F29 error code for more.
- Check your gas supply and prepayment meter.
- Thaw the condensate pipe if it has frozen.
- Check the flue outside for blockages.
- Reset the boiler.
- Book a Gas Safe engineer if F29 keeps appearing.
F32 Fan Speed Fault
The F32 code means the fan isn’t spinning at the speed the boiler expects, and on many models it also acts as a frost protection warning. In Scotland, a frozen condensate pipe is a very common cause, along with a blocked flue, a worn fan or a wiring fault. Read our F32 fault code guide for more.
- Find the condensate pipe outside and check it for ice.
- Thaw it with warm water or a hot water bottle.
- Check the flue terminal is clear.
- Reset the boiler.
- Book a Gas Safe engineer if the fan sounds noisy or the fault returns.
F33 Air Pressure Switch Fault
The F33 code appears on older Vaillant models that use an air pressure switch to check the fan and flue are working. A blocked flue, a cracked sensing tube, a weak fan or a faulty pressure switch can trigger it.
- Check outside that the flue terminal is clear.
- Reset the boiler once.
- Book a Gas Safe engineer to check the fan, pressure switch and tubing.
- Have any faulty part replaced.
F49 Low eBUS Voltage
The F49 code means there’s a problem with the low voltage connection between the boiler and its controls, such as a wired thermostat or programmer. A short circuit, a damaged cable or too many devices on the connection are the usual causes.
- Check whether any controls or thermostats have recently been changed.
- Switch the boiler off and on at the mains.
- Ask an engineer to check the control wiring for damage or shorts.
- Have any faulty controls or cables replaced.
F54 Gas Supply Problem
The F54 code is most often linked to a gas supply problem that stops the burner lighting, though it doesn’t appear on every Vaillant model. An empty prepayment meter, low gas pressure, a partly closed gas valve or a faulty gas valve in the boiler are common causes. Find out more in our F54 fault code article.
- Check other gas appliances work.
- Top up your prepayment meter if needed.
- Make sure the gas valve at the meter and under the boiler is open.
- Reset the boiler.
- Book a Gas Safe engineer if the fault continues.
F61 Gas Valve Control Fault
The F61 code means the circuit board can’t properly control the gas valve. A faulty gas valve, a damaged wiring harness, damp in the electrics or a failing circuit board are the main causes. Our F61 fault code guide goes into more detail.
- Reset the boiler once.
- Check for leaks around the boiler.
- If F61 comes back, stop resetting it.
- Book a Gas Safe engineer to test the gas valve and wiring.
F62 Gas Valve Slow To Shut Off
The F62 code means the gas valve took too long to close, so the flame lingered after the boiler switched off. A sticking gas valve, a dirty or damp electrode, earthing faults or a board fault can cause it. Read our full F62 fault code guide.
- Reset the boiler once.
- Don’t keep resetting it if the code returns.
- Book a Gas Safe engineer to test the gas valve and electrode.
- Ask for a combustion check after any repair.
F63 EEPROM Fault
The F63 code means there’s a problem with the memory chip on the boiler’s circuit board. It’s usually caused by a failing board, sometimes after a power surge.
- Switch the boiler off at the mains for a minute, then back on.
- If F63 remains, book a Gas Safe engineer.
- Have the circuit board tested and replaced if needed.
F64 Electronics Or Sensor Fault
The F64 code means the boiler has spotted a fault with the electronics or a sensor short circuit, often affecting the flow or return sensors. Damp, a failed sensor or a board fault are common causes.
- Check for leaks or damp around the boiler.
- Reset the boiler once.
- Book a Gas Safe engineer to test the sensors and circuit board.
- Have any faulty part replaced.
F65 Electronics Temperature Too High
The F65 code means the circuit board has got too hot. This can be caused by poor ventilation around the boiler, heat from a nearby leak or flue fault, or a failing board.
- Make sure the boiler cupboard isn’t packed full and has some airflow.
- Switch the boiler off and let it cool.
- Reset the boiler.
- Book a Gas Safe engineer if F65 returns.
F67 Flame Signal Implausible
The F67 code means the flame signal the boiler is receiving doesn’t make sense, such as a flame showing when there shouldn’t be one. A faulty electrode, damp on the board or a circuit board fault are the usual causes.
- Reset the boiler once.
- Check for damp or leaks near the boiler.
- Book a Gas Safe engineer to check the electrode and board.
- Replace any faulty parts.
F70 Invalid Device ID
The F70 code usually appears after a circuit board or display has been replaced, and it means the boiler’s identity code hasn’t been set correctly. It’s an engineer setup issue rather than a wear and tear fault.
- Contact the engineer who carried out the recent repair.
- Ask them to enter the correct device code for your boiler.
- Have the boiler fully tested afterwards.
F71 Flow Sensor Stuck At One Value
The F71 code means the flow sensor is showing the same temperature for too long, even though it should be changing. A faulty sensor, a sensor that has come loose from its pipe or poor water flow are the usual causes.
- Check the pressure and bleed radiators if needed.
- Reset the boiler.
- Book a Gas Safe engineer to check the flow sensor and its position.
- Have the sensor replaced if it’s faulty.
F72 Flow And Return Sensor Mismatch
The F72 code means the flow and return sensors are giving readings that don’t match as they should. A drifting sensor, a sensor that has lost contact with its pipe, damaged wiring or a board fault are common causes. Our F72 fault code guide explains more.
- Reset the boiler once.
- Check for any leaks near the electrics.
- Book a Gas Safe engineer to compare and test both sensors.
- Replace any faulty sensor or wiring.
F73 Water Pressure Sensor Signal Too Low
The F73 code means the water pressure sensor is sending a signal that’s too low, which can mean very low system pressure, a short circuit or a faulty sensor.
- Check the pressure gauge and top up to around 1.2 bar if low.
- Reset the boiler.
- If the pressure is fine but F73 remains, book a Gas Safe engineer.
- Have the pressure sensor or its wiring replaced.
F74 Water Pressure Sensor Signal Too High
The F74 code means the pressure sensor’s signal is too high, which can point to over pressurised water or a faulty sensor.
- Check whether the pressure gauge is reading above 2.5 bar.
- If it is, bleed a radiator carefully to bring it down to around 1.2 bar.
- Make sure the filling loop valves are fully closed.
- Book a Gas Safe engineer if the pressure keeps rising or the fault remains.
F75 No Pressure Rise When The Pump Starts
The F75 code means the pump started but the boiler didn’t detect the small pressure rise it expects. A blocked or faulty pressure sensor, an airlocked or failing pump, low pressure or a waterlogged expansion vessel are the main causes. Read our in-depth F75 fault code guide.
- Check the pressure and top up to between 1 and 1.5 bar.
- Bleed all radiators to remove trapped air.
- Top the pressure back up after bleeding.
- Reset the boiler.
- Book a Gas Safe engineer to check the pump and pressure sensor if F75 returns.
F76 Heat Exchanger Overheat Protection
The F76 code means the heat exchanger got hot enough to blow its thermal fuse, which can’t be reset. Poor circulation from a failing pump, sludge, low pressure or a faulty fuse are the usual causes. Our F76 fault code guide covers it in full.
- Switch the boiler off and leave it to cool.
- Note any noises or other codes you saw beforehand.
- Book a Gas Safe engineer to replace the thermal fuse.
- Have the cause of the overheating fixed before the boiler is used again.
F77 Condensate Pump Or Flue Damper Fault
The F77 code means there’s a problem with an accessory such as a condensate pump or flue gas damper, on systems that have one fitted. A blocked or failed condensate pump, a faulty damper or a wiring issue are the usual causes.
- Check whether a condensate pump is fitted and if it has power.
- Look for water backing up around the condensate pipe.
- Book an engineer to check the accessory and its wiring.
- Have the faulty part repaired or replaced.
F78 Hot Water Sensor Fault With External Controller
The F78 code appears when the boiler is linked to an external controller, and it means the hot water outlet sensor isn’t communicating properly. It’s usually a wiring or setup issue, or a faulty sensor.
- Check whether any controls have recently been changed.
- Reset the boiler.
- Ask an engineer to check the controller setup and sensor wiring.
- Replace any faulty sensor or connection.
F83 Dry Fire Temperature Change Too Small
The F83 code means the burner lit but the sensors saw little or no temperature change, which can suggest there isn’t enough water in the heat exchanger. Low pressure, air, a weak pump, a loose sensor or closed valves are common causes. Read our full F83 fault code guide.
- Check and top up the pressure.
- Bleed your radiators.
- Make sure the valves under the boiler are open.
- Reset the boiler.
- Book a Gas Safe engineer if the fault continues.
F84 Flow And Return Difference Implausible
The F84 code means the flow and return temperatures don’t make sense, such as the return being hotter than the flow. Swapped sensors, pipes connected the wrong way round, a faulty sensor or crossed wiring are usual causes, and it often appears after a repair or new installation. See our F84 fault code guide for more.
- Think back to whether any recent work was done on the boiler.
- Contact the engineer or installer who carried it out.
- Have them check the sensor positions and pipe connections.
- Reset the boiler once corrected.
F85 Sensors Fitted To The Wrong Pipe
The F85 code means the flow and return sensors appear to be fitted on the same pipe or in the wrong position. It’s almost always caused by sensors being refitted incorrectly during a repair.
- Contact the engineer who last worked on the boiler.
- Ask them to check and correct the sensor positions.
- Have the boiler tested over a full heating cycle.
F86 Underfloor Heating Contact Open
The F86 code appears on systems with underfloor heating, and it means the safety thermostat on the underfloor circuit has opened, often because the water going into the floor got too hot. A faulty thermostat or wiring can also cause it.
- Check the settings on your underfloor heating controls.
- Let the system cool down.
- Reset the boiler.
- Ask an engineer to check the underfloor thermostat and mixing valve if it returns.
F87 Ignition Electrode Not Connected
The F87 code means the boiler can’t detect the ignition electrode, usually because a lead has come loose or been damaged.
- Reset the boiler once.
- Book a Gas Safe engineer to check the ignition lead and electrode.
- Have any loose or damaged parts refitted or replaced.
F88 Gas Valve Not Connected
The F88 code means the boiler can’t detect the gas valve, usually because the plug or wiring has come loose or been damaged.
- Reset the boiler once.
- Book a Gas Safe engineer to check the gas valve connection.
- Have the wiring repaired or replaced.
F89 Pump Not Connected Or Incorrect
The F89 code means the boiler can’t detect the pump properly, or the pump fitted isn’t the right type for the boiler. It’s common after a pump replacement or when a plug has worked loose.
- Note whether a new pump has recently been fitted.
- Contact the engineer who replaced it.
- Have the pump connection checked or the correct pump fitted.
Is Your Vaillant Boiler Showing Fault Codes Again And Again? Get A Free New Boiler Quote From SwitchHeat
If your Vaillant boiler keeps showing fault codes, it’s usually a sign that it’s working harder than it should. A one off code is often nothing to worry about, but repeated lockouts point to worn parts, ageing electronics or a tired heating system. Each engineer visit, diagnostic check and replacement part adds up, and on an older boiler, one repair is often followed by another.
Most boilers last around 10 to 15 years. If yours is getting close to that age and you’re regularly seeing codes like F22, F28, F29 or F75, it’s well worth comparing the cost of ongoing repairs with a brand new boiler. A modern, A rated boiler gives you better efficiency, lower energy bills, a long manufacturer’s warranty and the peace of mind that your heating and hot water will be there when you need them.
Request your free, no obligation new boiler quote today and say goodbye to fault codes for good.
At SwitchHeat, we install new boilers for homeowners and landlords across Dumbarton, Glasgow, Ayrshire, Renfrewshire, Lanarkshire and the wider Central Scotland area. Our friendly team will give you honest advice, a clear fixed price and a fast, tidy installation.
Frequently Asked Questions
What Is The Difference Between F Codes And S Codes On A Vaillant Boiler?
F codes on a Vaillant boiler are fault codes that show something has gone wrong, while S codes are status codes that simply show what the boiler is doing at that moment, such as heating or ignition. An S code on its own isn’t usually a problem.
How Do I Find Out Which Vaillant Boiler Model I Have?
You can find your Vaillant boiler model on the data plate, which is usually behind the front panel or underneath the boiler. It lists the model name, such as ecoTEC plus or ecoTEC pro, and the serial number.
Can An Engineer See Past Fault Codes On My Vaillant Boiler?
Yes, a Gas Safe engineer can see past fault codes using the boiler’s fault memory in the installer menu. This shows which faults have happened recently, helping them spot patterns and find the root cause faster.
Should Landlords Keep A Record Of Boiler Fault Codes?
Yes, landlords should keep a record of any fault codes tenants report, along with dates and repairs carried out. It helps engineers diagnose recurring issues and supports your gas safety records for each property.
Do Vaillant Fault Codes Mean The Same On Every Model?
Vaillant fault codes mean largely the same across most ecoTEC models, but some older or specialist boilers use slightly different codes. Always check the manual for your exact model if a code doesn’t match what you’d expect.
-