Vokera Boiler Error Codes: Causes & How To Fix

Vokera Boiler Error Codes: Causes & How To Fix

The most common Vokera boiler error codes are low pressure (A40), ignition failures (A01), circulation problems (A44), and airflow or flue-related faults (A04).

In many cases, these problems start small but get worse over time if ignored. The good news is that some can be safely resolved at home, while others simply need a qualified engineer. Knowing the difference is what saves you time, money, and stress.

Vokera Boiler Codes: At A Glance

Below is a quick overview of the Vokera error codes and what your boiler is trying to tell you.

Error Code Meaning
A01 Ignition failure
A02 False flame detection
A03 Overheating
A04 Fan or flue fault
A06 Hot water sensor fault
A07 Heating sensor fault
A40 Low pressure
A41 Pressure sensor fault
A44 Circulation fault
A51 Gas valve fault
A77 Flue thermostat triggered

Excellent ★★★★★Trustpilot
9.9/10 from 40 reviews on Checkatrade
4.9★★★★★ 44 reviews on Google
  • Available Finance Options
  • Quality Workmanship
  • Transparent Pricing
  • Fast Response When You Need Us Most
  • Accredited & Qualified Engineers

Get An Online Boiler Quote

What Causes Vokera Boiler Error Codes?

The causes of the Vokera boiler error codes depend on the fault, but most issues relate to gas supply, system pressure, water flow, or internal sensors.

A01 Ignition Failure

The A01 ignition failure error code means the boiler has attempted to light but failed to establish a flame.

This usually happens because the boiler is not receiving gas properly or cannot ignite it. In real terms, that could be something as simple as your gas supply being interrupted, or more technical like a worn ignition electrode that can no longer spark effectively. 

Over time, components inside the boiler degrade due to heat and usage, and ignition parts are one of the most common to fail. In some cases, moisture or debris inside the combustion chamber can also interfere with ignition.

How to fix:

  1. Check that your gas supply is active by turning on another gas appliance such as your hob
  2. If you use a prepaid meter, confirm there is enough credit
  3. Locate the reset button on your boiler and press it once
  4. Wait a few minutes to see if the boiler attempts to relight
  5. If the fault returns, avoid repeated resets as this can damage components
  6. Contact a Gas Safe registered engineer to inspect the ignition system and gas valve

A02 Flame Detection Fault

The A02 flame detection fault code means the boiler believes a flame is present when there shouldn’t be one.

This is typically caused by a faulty flame sensor sending incorrect signals to the boiler’s control board. The sensor’s job is to confirm that a flame is present during operation. When it malfunctions, the boiler becomes confused and shuts down as a safety precaution. Electrical issues or a failing PCB can also cause false readings.

How to fix:

  1. Turn the boiler off completely using the main power switch
  2. Wait at least 30 seconds before turning it back on
  3. Press the reset button
  4. Observe whether the boiler starts normally
  5. If the error persists, the flame sensor or PCB will need professional testing and likely replacement

A03 Overheating Fault

The A03 overheating fault means the boiler temperature has exceeded safe limits.

This usually points to poor water circulation within your heating system. When water cannot move freely through the pipes and radiators, heat builds up inside the boiler instead of being distributed around the home. This is often caused by sludge build-up, trapped air, or a failing pump. Over time, central heating systems naturally accumulate debris, especially in older properties.

How to fix:

  1. Turn off your heating system and allow it to cool down
  2. Bleed all radiators in your home to release trapped air
  3. Check that all radiator valves are fully open
  4. Turn the boiler back on and reset it
  5. Monitor whether radiators heat evenly
  6. If some remain cold or the fault returns, a power flush or pump repair may be required

A04 Fan Or Flue Fault

The A04 fan or flue fault indicates a problem with how your boiler expels waste gases.

Your boiler relies on a fan to push harmful gases safely out through the flue. If the flue is blocked or the fan is not working correctly, the boiler will shut down immediately for safety reasons. In UK homes, this is often caused by external blockages such as leaves, debris, or even bird nests in the flue terminal.

How to fix:

  1. Go outside and visually inspect the flue outlet
  2. Remove any visible obstructions such as leaves or debris
  3. Return to the boiler and press the reset button
  4. Listen for the fan starting up when the boiler attempts to fire
  5. If the fault remains, the fan or internal airflow components will need professional inspection

At SwitchHeat, we service boilers across Glasgow, Ayrshire, Renfrewshire, Lanarkshire and Dumbarton every single day. We don’t just reset fault codes. We find the root cause and fix it properly.

A professional service helps to:

  • Catch faults early before they become breakdowns
  • Improve heating performance and efficiency
  • Reduce energy bills
  • Keep your property compliant as a landlord

Excellent ★★★★★Trustpilot
9.9/10 from 40 reviews on Checkatrade
4.9★★★★★ 44 reviews on Google
  • Available Finance Options
  • Quality Workmanship
  • Transparent Pricing
  • Fast Response When You Need Us Most
  • Accredited & Qualified Engineers

Get An Online Boiler Quote

A06 Hot Water Sensor Fault

The A06 hot water sensor fault means the boiler cannot accurately measure hot water temperature.

This usually happens when the sensor becomes faulty or wiring connections loosen over time. As a result, the boiler cannot regulate water temperature properly, leading to inconsistent hot water or complete shutdown.

How to fix:

  1. Reset the boiler
  2. Run your hot taps and check if water temperature is stable
  3. If hot water fluctuates or the error returns, switch off the boiler
  4. Arrange for an engineer to test and replace the sensor if needed

A07 Central Heating Sensor Fault

The A07 central heating sensor fault relates to incorrect readings from the heating side of the system.

When the sensor fails, the boiler cannot accurately control the temperature of water flowing to your radiators. This can lead to uneven heating or the boiler shutting down unnecessarily.

How to fix:

  1. Reset the boiler
  2. Turn your heating on and monitor radiator performance
  3. If heating is inconsistent or the error returns, the sensor will need replacing
  4. Book a qualified engineer to carry out the repair

A40 Low Pressure Fault

The A40 low pressure fault is one of the most common Vokera boiler issues and means the system pressure has dropped below the required level. If you have an Ariston instead, low pressure appears as code 108, among others covered in our Ariston boiler error codes guide.

Pressure naturally decreases over time, especially after bleeding radiators or due to small leaks in the system. Without enough pressure, water cannot circulate properly, so the boiler shuts down to protect itself. Baxi boilers show a similar low pressure warning as the Baxi boiler H0207 error code, which we explain in a separate guide.

How to fix:

  1. Locate the pressure gauge on your boiler
  2. Check if the reading is below 1 bar
  3. Find the filling loop, usually a silver braided hose under the boiler
  4. Slowly open the valves on the filling loop
  5. Watch the pressure gauge as it rises
  6. Close the valves once it reaches between 1 and 1.5 bar
  7. Reset the boiler
  8. If pressure continues to drop regularly, a leak or faulty component may be present

A41 Pressure Sensor Fault

The A41 error code means the boiler cannot correctly read system pressure.

Even if the pressure is normal, the boiler may behave as if it isn’t because the sensor is faulty. This is usually an internal component issue rather than something caused by the wider heating system.

How to fix:

  1. Reset the boiler
  2. Check the pressure gauge to confirm actual pressure levels
  3. If the error persists despite normal pressure, the sensor needs replacing
  4. Contact an engineer to carry out the repair safely

A44 Circulation Fault

The A44 error code means water is not moving effectively through your system.

This is often due to sludge, blockages, or a failing pump. Over time, central heating systems collect rust and debris which restricts water flow. This reduces efficiency and can eventually stop the boiler working altogether.

How to fix:

  1. Turn on your heating and check each radiator
  2. Identify any cold spots or radiators that are not heating
  3. Bleed radiators to remove trapped air
  4. Reset the boiler
  5. If problems continue, a power flush may be required to clear sludge
  6. In some cases, the pump may need repair or replacement

A51 Gas Valve Fault

The A51 gas valve fault indicates the boiler cannot control the flow of gas properly.

This is a critical component that regulates how much gas enters the burner. If it fails, the boiler cannot operate safely. Electrical faults or wear and tear are common causes.

How to fix:

  1. Reset the boiler once
  2. Do not attempt to access internal components
  3. Turn the boiler off if the fault persists
  4. Contact a Gas Safe registered engineer immediately

A77 Flue Thermostat Fault

The A77 flue thermostat fault means the temperature in the flue has exceeded safe levels.

This is usually linked to restricted airflow or poor ventilation. When heat cannot escape properly, it builds up and triggers a safety shutdown.

How to fix:

  1. Check the external flue for blockages
  2. Ensure vents around the boiler are not obstructed
  3. Reset the boiler
  4. If the issue returns, a full flue inspection is required

Why Should You Book A Boiler Service With SwitchHeat?

SwitchHeat provides expert boiler servicing and maintenance across Central Scotland, including Glasgow, Ayrshire, Renfrewshire, Lanarkshire and Dumbarton. Whether it’s a recurring fault code, pressure issue, or full system clean, our engineers will get your heating back on track quickly.

Book your boiler service with SwitchHeat today and avoid costly breakdowns later.

Frequently Asked Questions

Do Vokera Error Codes Indicate Immediate Boiler Failure?

Not always. Some codes are early warnings, but others indicate faults that will stop the boiler working entirely if not addressed.

Can Weather Conditions Cause Boiler Error Codes?

Yes, freezing temperatures can cause condensate pipes to freeze, which may trigger certain fault codes.

Are Error Codes The Same Across All Vokera Models?

Most codes are similar, but exact meanings can vary slightly depending on the model, so always check your manual.

Can A Dirty System Trigger Error Codes?

Yes, sludge and debris in the system can cause circulation issues, overheating, and reduced efficiency.

Should Landlords Act Immediately On Error Codes?

Yes, especially if tenants are affected. Delays can lead to compliance issues and more expensive repairs.

Excellent ★★★★★Trustpilot
9.9/10 from 40 reviews on Checkatrade
4.9★★★★★ 44 reviews on Google
  • Available Finance Options
  • Quality Workmanship
  • Transparent Pricing
  • Fast Response When You Need Us Most
  • Accredited & Qualified Engineers

Get An Online Boiler Quote

Good news, we install Boilers in your area!

Instant online quotes, finance available & next day installation.

Get a quote